Do basement ceilings need to be fire rated?

Do basement ceilings need to be fire rated?

Fire blocking is required by most local building code departments when a home owner finishes their basement. The block is nothing more than a 2″ x 6″ or fire-rated drywall turned flat and attached to the bottom of the first floor joists.

What does 1 hour fire rating mean?

A “one-hour” fire rating is given to an assembly consisting of various building materials that can resist the exposure of a standardized fire exposure for one hour. A few acceptance criteria for the test stipulate that the fire from the gas-fired furnace cannot penetrate through the assembly during the test.

What is fire rated ceiling?

An Underwriters’ Laboratories (UL) fire resistant rated ceiling system provides separation between the elements of the building services (i.e. ductwork and piping) and the occupied space below. A UL fire resistant rated ceiling also provides a known, specified fire resistance period.

Is 5/8 drywall required for basement ceilings?

3 Answers. 5/8″ drywall is rarely required in single-family residences. It was used historically because ceiling joists are often 24″ on center, and 5/8 resists sag. You can certainly use no-sag 1/2″ if you like.

How thick should basement ceiling drywall be?

5/8-Inch-Thick Drywall When installed on ceilings, 5/8-inch-thick panels are less susceptible to sagging between the joists than 1/2-inch panels. Adding popcorn texture or another type of heavy surfacing material can add to the weight problem, making 5/8-inch drywall a better choice for ceilings.

What is needed for Fireblocked?

Fireblocks are required between floors, between a top story and a roof or attic space, in furred spaces or the cavities between studs in wall assemblies, at connections between horizontal and vertical spaces created in floor joists or trusses, soffits, drop or cove ceilings, combustible exterior wall finishes and …

When should fire blocking be installed?

Fire blocking is needed when wood and steel stud walls only have drywall on one side because the fire is now able to go around the top plate and up into the framing above. Sometimes it is hard to see where you need fire blocking.

What makes a 1 hour fire rated ceiling?

Type X fire rated gypsum drywall that is 5/8 -inch (15.9mm) thick and installed on each side of nominal 2-inch x 4-inch (38x89mm) wood studs spaced 16-inch (400mm) o.c. or 3-5/8 inch (610 mm) steel studs spaced 24” o.c. has a minimum fire rating for the assembly of 1 hour, which is a typical requirement for many …

Does a 1 hour fire rated wall require a fire damper?

Q: Are fire dampers required in one-hour fire-rated walls if the facility is fully sprinkled? A: According to NFPA 90A (1999 edition), one-hour fire-rated barriers do not require fire dampers in fully ducted HVAC systems, unless the one-hour fire-rated barrier is a vertical shaft.

How do you determine if a ceiling is fire rated?

Fire Ratings of Ceiling Tiles The rating is looked at by both the inspector and the local fire marshal as they determine the safety of the building. There are two different levels of fire rating to be aware of: flame spreading rate and fire barrier rating.

What does 2 hour fire rating mean?

3. When a building or system is said to have a 2-hour fire rating, what does that mean? It means that the system has satisfied the requirements for a 2-hour rating specified in a relevant standard test.

What is a fire rated ceiling?

An Underwriters’ Laboratories (UL) fire resistant rated ceiling system provides separation between the elements of the building services (i.e. ductwork and piping) and the occupied space below. A UL fire resistant rated ceiling also provides a known, specified fire resistance period.

What is 1 hour fire rated Assembly?

A “one-hour” fire rating is given to an assembly consisting of various building materials that can resist the exposure of a standardized fire exposure for one hour. It was developed to evaluate the performance of building elements during an intense fire exposure (for example,…

What is the fire rating for ceiling tiles?

Fire Rating All interior finishes with ceiling tiles must be fire code Class A (1) for both smoke and flame. While most PVC ceiling tiles are rated A(1) some are only class C(3) even though they claim the A(1) rating. Always request a spec sheet with ASTM E84 report for any ceiling tile being considered.